Edit Relay Definition

 
Relay edit window in GS Manager - Access in Astrow Web
 
Description: A description of the relay.
Door terminal: The terminal that activates the relay. Use the dropdown list to set it manually:
 
 
Operation mode: Here you can define the relay function:
 
  • Access clocking: The relay responds to a valid access clocking and activates an access mechanism during a number of seconds defined.
  • Activated by alarm: The relay will be activated by an alert (see more at Access Inputs).
  • Activated by GLOBAL alarm: The relay will be activated by the global alert (see more at Access Inputs).
  • Activated by LOCAL alarm: The relay will be activated by the local alert (see more at Access Inputs).
  • Continuous on: The relay will be permanently activated.
  • Continuous off: The relay will be taken out of service.
  • Every minute activation: The relay will be activated each minute during a number of seconds (external clock synchronization).
  • Reset to original mode: The relay will be reset to its original state
  • Signal program: The relay will be activated for a number of seconds on time set in the signal definition (see more at Access Signals).
 
 
Duration: The number of seconds the relay will be activated.
Initial status: The status of the relay at rest (not supplied).
 
 
Disable PA: Disable permanent activation. When selected, this option will prevent the relay from being permanently activated (to protect certain locks from long term activation).