iT300/iT30 Terminal Configuration
To add a new terminal configuration, go to
Communication - Terminal Configuration and click
for iT300 and for iT30.
|
Tab General when Adding a new terminal configuration for iT30 in Astrow Web
|
Fill in the following parameters:
Name: The name of the new defined signal.
Signal: This drop-down list contains all existing signal program definitions (see Signal Definitions). You can either select a signal program to be applied, or select (None) (default value) if you don't use any signals.
Signal exceptions: This drop-down list contains all existing signal exceptions definitions (see Signal Exceptions). You can either select a signal exception to be applied or select (None) (default value) if you don't use any signal exceptions.
Card input mode: Select Numeric input enabled (default value) if generating bookings via keypad is allowed, or Numeric input disable if bookings can be made only using a card.
MC input mode: This field specifies how to enter an MC code (management code) into the terminal. There are 3 options available:
-
Selection: Enables the selection of the MC code from the terminal.
-
Numeric input: Enables the key in of the numeric MC from the terminal keypad.
-
Numeric input (+ description): With this option, a description of the MC will also be displayed on the terminal after pressing the MC code.
CC input mode: This field specifies how to enter a CC code (cost center code) into the terminal. There are 3 options available, the same as for the MCs mentioned above.
Booking relay: Select Relay 1 or Relay 2 if you need to activate a relay when booking. If you don't use any relays, just leave (None).
PIP email: This sends the existing PIP situation via email when the user presses F5 on the terminal. This is important moreover in emergency situations. You can deactivate this function by selecting Disable; however, this is activated by default without PIN authentication. You can also activate it with PIN authentication.
Password: Define the password to be entered on the terminal when viewing/changing the parameters. This password has a minimum 1 and maximum 8 digits.
Confirm password: Re-enter the same password to confirm.
Open door authentication: Check this option if a relay has to be activated by entering a password on the terminal (without making a clocking). If checked, some options will be required:
-
Password: Define the password to be entered on the terminal to activate a relay. This password has a minimum 1 and maximum 8 digits.
-
Confirm password: Re-enter this same password to confirm.
-
Open Door Relay: Select the relay to be activated after the password.
Go to tab Terminals to add the terminals.
|
Tab General filled when Adding a new terminal configuration for iT300 in Astrow Web
|
In edit mode, you can make the changes in the same manner as described above:
|
Editing a terminal configuration for iT300 in Tab General in Astrow Web
|
You can also edit the terminal later or from the terminal definition.